National annexes

Where nationally determined parameters change the answer, how to select the right annex, and what to state in the report.

Design checks 4 min read

A Eurocode is not usable on its own. Each country publishes a National Annex setting the nationally determined parameters: partial factors, ψ values, choices between alternative methods, and limits the base document leaves open. The same model checked under two annexes gives different answers, and both are correct.

Choosing the annex

Set it at project level, before you run any check. Every new Eurocode check starts on it. A check can also name its own under National annex on its Setup tab, and the arrow beside the field takes it back to the project's. An annex applies to a whole check, not to a member, because a mixed set of parameters is never valid. AISC and IBC modules take no annex.

The right annex is the one for the country where the structure is built, not where you or the client are based.

What happens to values already set

An annex writes its values into the check's parameters when it is chosen, and the run reads the parameters. So a stored value is never reinterpreted behind your back:

  • Choosing another annex on a check moves each parameter still at the old annex's default to the new annex's. One you changed stays, and the check names it: Kept as set, not what ČSN EN gives: γ_M1.
  • Apply annex defaults beside that notice puts those parameters back to the annex's values.
  • Changing the project's annex moves nothing in an existing check. A check that reads the project's annex shows the same notice for whatever now disagrees, with the same button.
  • A limit you stated yourself is not replaced by an annex's default. Picking another row of the annex's own table is not a disagreement either.
  • A value we don't hold for that annex keeps EN's own, and the setup says so.

What an annex typically changes

ParameterBase recommendationCommonly varied
Combination equations6.10, or 6.10a/6.10bWhich pair is permitted or required
(reduction on permanent)0.85Yes
, , Table A1.1 valuesYes, by category
(steel cross-section)1.00Yes — 1.05 in Italy and Norway
(steel buckling)1.00Yes — 1.10 in Germany
(fracture, connections)1.25Yes — 1.10 in the UK
Deflection limitsNone — EN 1990 A1.4 leaves them to the annexAlways national
Snow and wind mapsNot in the base document at allAlways national

The mixed-jurisdiction problem

Projects designed in one country and built in another are common, and so is a client specification that overrides parts of the annex. Where that happens:

  • Use the annex of the country of construction as the base.
  • Apply project-specific overrides explicitly, one by one, as documented decisions.
  • Never mix parameters from two annexes because one gives a more convenient number. The factors within an annex are calibrated together; cherry-picking breaks the calibration that makes the target reliability meaningful.

Actions are national too

Snow load, wind speed, seismic hazard and thermal actions come from national maps and tables in EN 1991. Elementarium does not generate site actions from a location. You determine the characteristic values and apply them as load cases. The annex governs how those actions are combined, not what they are.

What to state in the report

  • The Eurocode parts used, with their year.
  • The National Annex applied.
  • Any parameter overridden from the annex default, with its value and the reason.
  • Which combination equations were used: 6.10 or 6.10a/6.10b.

Coverage in this release

Around forty entries ship, grouped by family in the project settings:

FamilyWhat is carried
EurocodeThe base EN recommended values, plus a named annex for every EU and EFTA country and several beyond — ÖNORM, NBN, ČSN, DS/EN, DIN, NF, UNI, NEN, NS, PN, SR, SS, SIST, UNE, TS, BS EN and the rest
United StatesIBC / AISC 360, where the method — LRFD or ASD — replaces
BrazilABNT NBR 8800
SwitzerlandSIA 26x, with
CustomNothing prefilled; you set the factors yourself

Most Eurocode entries adopt the EN recommended values, because that is what those annexes do. Where an annex is known to depart (Germany, Italy, Norway, Spain and the UK among them) its own values are carried instead.

An annex sets these on a check, where the module reads them and we hold the value:

  • , and ; for stainless steel, its own and ;
  • LTB factor f and LTB curves for §6.3.2.3, such as the UK, French, Finnish, Belgian, Portuguese, Malaysian and Singapore variants;
  • the deflection, drift and timber limit rows of the serviceability checks, and under ČSN.

The setup also says which of Annex A and Annex B the annex takes for the §6.3.3 interaction factors. Only Annex B is in the check, so where the annex asks for Annex A it says that the result differs from the annex's choice.

Everything else an annex changes (permitted combination expressions, ψ values, site actions) is yours to enter, and the combination generator's factors are editable fields for exactly that reason.